atmosphere.knaufinsulation.usAtmosphere Air Duct Board | Knauf Insulation

atmosphere.knaufinsulation.us Profile

atmosphere.knaufinsulation.us

Maindomain:knaufinsulation.us

Title:Atmosphere Air Duct Board | Knauf Insulation

Description:Knauf Insulation Atmosphere™ Air Duct Board with ECOSE® Technology, is a rigid glass mineral wool. Learn more about our duct board insulation here.

Discover atmosphere.knaufinsulation.us website stats, rating, details and status online.Use our online tools to find owner and admin contact info. Find out where is server located.Read and write reviews or vote to improve it ranking. Check alliedvsaxis duplicates with related css, domain relations, most used words, social networks references. Go to regular site

atmosphere.knaufinsulation.us Information

Website / Domain: atmosphere.knaufinsulation.us
HomePage size:101.109 KB
Page Load Time:0.910538 Seconds
Website IP Address: 40.86.86.144
Isp Server: Microsoft Corporation

atmosphere.knaufinsulation.us Ip Information

Ip Country: United States
City Name: Redmond
Latitude: 47.682899475098
Longitude: -122.12090301514

atmosphere.knaufinsulation.us Keywords accounting

Keyword Count

atmosphere.knaufinsulation.us Httpheader

Cache-Control: private
Content-Length: 100360
Content-Type: text/html; charset=utf-8
Server: Microsoft-IIS/10.0
X-AspNetMvc-Version: 5.2
X-AspNet-Version: 4.0.30319
Request-Context: appId=cid-v1:a2991a8a-7c07-447c-ab86-133d6630a440
Access-Control-Expose-Headers: Request-Context
X-Powered-By: ASP.NET
Date: Fri, 17 Jul 2020 20:15:35 GMT

atmosphere.knaufinsulation.us Meta Info

charset="utf-8"/
content="width=device-width, initial-scale=1.0" name="viewport"/
content="ie=edge" http-equiv="X-UA-Compatible"/
content="Knauf Insulation Atmosphere™ Air Duct Board with ECOSE® Technology, is a rigid glass mineral wool. Learn more about our duct board insulation here." name="description"
content="" name="keywords"
content="index, follow" name="robots"
content="US" name="country-variant"/
content="en" name="language"/
content="Products" name="page-grouping"/
content="Product Detail" name="page-subgrouping"/
content="" name="search-description"

40.86.86.144 Domains

Domain WebSite Title

atmosphere.knaufinsulation.us Similar Website

Domain WebSite Title
atmosphere.knaufinsulation.usAtmosphere Air Duct Board | Knauf Insulation
aironehvac.comAir One - Heating and Air Conditioning | Duct Cleaning
nadca.comNational Air Duct Cleaners Association NADCA
pringles-inc-oh-4.hub.bizPringles in Dublin, OH - Duct Cleaning Heating & Air Conditioning Systems
ductdetectives.comDuct Detectives – Commercial HVAC Duct Cleaning Sealing
coler.comInsulation Company | Spray Foam Insulation Company - Coler Insulation
momper.comInsulation Contractors Fort Wayne, IN | Retrofit Insulation in Elkhart
coreinsulators.comCore Insulation | Mechanical Insulation Contractors Arkansas | Home
roof.atlasrwi.comRigid Foam Roof Insulation | Atlas Roofing Insulation
innersafe.knaufinsulation.usCommercial and Residential Fiberglass Insulation | Knauf Insulation
store.airslamit.comAir Suspension Parts | Air Ride Compressors | Air Tank Kits | Air Bag Suspensions Kits | Air Lift Va
airslamit.comAir Suspension Parts | Air Ride Compressors | Air Tank Kits | Air Bag Suspensions Kits | Air Lift Va
airliftcompany.comAir Lift® Air Springs | Air Suspension Kits, Air Ride Suspension & Air Bags
advantone.comAdministration – Advantone Atmosphere
flanagansonmain.comFlanagan's On Main - Irish Pub & Restuarant - Family Friendly Atmosphere

atmosphere.knaufinsulation.us Traffic Sources Chart

atmosphere.knaufinsulation.us Alexa Rank History Chart

atmosphere.knaufinsulation.us aleax

atmosphere.knaufinsulation.us Html To Plain Text

Products Products > Pipe Insulation Batts Pipe and Tank Blown-in Insulation Board Rolls Elevated Temperature Air Sealant Duct Board Basement Wall Duct Wrap Metal Building Insulation Duct Liners Wall and Ceiling Liner OEM How to Choose the Right Insulation Fiberglass Insulation The smart choice to make spaces more comfortable and energy efficient. R-Value The ability to resist heat flow — insulation's thermal resistance. Thermal Properties Ability to provide thermal resistance for comfort and efficiency. Insulating for Sound Sound absorption characteristics, helping reduce noise transmission. Applications Applications Walls Pipe Insulation Floor High Temperature Equipment Mid-Floor HVAC Ceiling Metal Building Attics Filtration Roof Deck Insulation Sound Control Basement and Crawlspace Air Sealing Project Type Commercial Hospitality Modular Construction Office Buildings Warehouses Restaurants Retail Industrial Manufacturing Facilities Chemical Processing Petro Chemical Power Generation Institutional Healthcare Educational Buildings Other Institutional OEM Appliance Automotive Theaters & Auditoriums Transportation Residential Single Family Multi-Family Improvement & Retrofit Manufactured Housing Tools & Documents Documents > Data / Submittal Sheets Safety Data Sheets Installation Guides Certificates of Insulation Specifications Attic and Cavity Wall Card Load Data Guides Warranty Tax Credits Fact Sheets Sell Sheets Brochures Equipment Lists EPD GREENGUARD UL Validations Case Studies Service Guidelines Tools & More FAQs Case Studies Technical Support Certifications BIM - Revit Project Builder NAIMA 3E Plus English (United States) Back United States Canada Corporate Albania Algeria Australia Austria Belgium Bosnia Bulgaria Croatia Czech Republic Denmark Estonia Finland France Germany Greece Hungary Ireland Italy Japan Latvia Lithuania Luxembourg Macedonia Mexico Montenegro Morocco Netherlands New Zealand Norway Poland Portugal Romania Russia Serbia Singapore Slovakia Slovenia South Korea Spain Sweden Switzerland Tunisia Turkey UAE UK Ukraine About Blog Careers Contact Us Where To Buy COVID-19: What We're Doing & What You Need To Know. Learn more Duct Board Insulation / Atmosphere Air Duct Board Atmosphere™ Air Duct Board Excellent acoustic and thermal characteristics make for quiet, efficient air delivery. Unwanted “booms” and “cracks” caused by sheet metal ducts, minimized. This formaldehyde-free board with a lightweight non-woven brown mat on the airstream surface is made with ECOSE ® Technology. Applications HVAC Certifications Data Sheet (0.45MB PDF) Safety Data Sheet (1.67MB PDF) View All Downloads BIM (REVIT) Product Features Proven Performance Engineered for high thermal and acoustical performance. Helps maintain temperatures and reduce noise generated by air turbulence and mechanical equipment. ECOSE® Technology Our patented, bio-based binder is a smarter alternative to using phenol formaldehyde. It’s been foundational in our commitment to sustainability. For the world we live in. Versatile Fabrication Simple, streamlined fabrication — done in shop or on the job site. Multiple sizes, minimal capital requirements and only one trade is required to fabricate and install. Product Details Technical Data Technical Data Property (Unit) Test Performance Corrosiveness ASTM C665 Does not accelerate corrosion of steel (Insulation) Corrosion ASTM C1617 Pass (Insulation) Maximum Service Temperature ASTM C411 250° F (121° C) (Insulation) Wator Vapor Permeance ASTM E96, Procedure A 0.02 perms or less Water Vapor Sorption (by weight) ASTM C1104 Less than 5% Flexural Rigidity NAIMA AHS-100-74 Available in 2 stiffness values: El-475 and El-800; Flexural rigidity (El) is the product of Young's modulus of elasticity (E) and moment of inertia (I) Air Velocity UL 181 Max. 5,000 ft./min. (1,524 m/min.) Tested to 12,500 ft./min. (3,810 m/min.) Internal Static Pressure UL 181 Maximum ±2" water (498 pascals [Pa]) Microbial Growth ASTM C1338, ASTM G21, UL 181 Pass, does not support the growth of fungi or bacteria Surface Burning Characteristics (flame spread/smoke developed) ASTM E84, UL 723 FHC 25/50; UL Listed Forms Available Forms Available Type Size* Edge Pieces/Carton** EI-475 1" (25 mm) 48" x 96" (1219 mm x 2438 mm) Shiplap 8 EI-800 48" x 120" (1219 mm x 3048 mm) Butt, Shiplap 6 EI-800 1.5" (38 mm) 48" x 120" (1219 mm x 3048 mm) Shiplap 4 2" (51 mm) 48" x 120" (1219 mm x 3048 mm) Butt, Shiplap 3 *Other lengths available on custom order basis. **Palletized packaging available on request. Thermal Resistance R & Thermal Conductivity K Thermal Resistance R | ASTM C518 Mean Temperature 75° F (24° C) Thickness R-Value (R.S.I) 1" (25 mm) 4.3 (0.76) 1.5" (38 mm) 6.5 (1.14) 2" (51 mm) 8.7 (1.53) “R” Units ft2 ∙ hr ∙ ˚F BTU m2 ∙ ˚C W) Thermal Conductivity K | ASTM C177 Mean Temperature 75° F (24° C) K-Value EI-475 and EI-800 0.23 (.033) “k” Units BTU ∙ in ft2 ∙ hr ∙ ˚F W m2 ∙ ˚C) Sound Absorption Coefficients Sound Absorption Coefficients | ASTM C423, Type A Mounting Octave Band Center Frequency (Cycles/Sec.) Thickness 125 250 500 1000 2000 4000 NRC 1" (25 mm) 0.03 0.25 0.62 0.92 1.03 0.97 0.70 1.5" (38 mm) 0.02 0.44 0.96 1.17 1.16 1.12 0.95 2" (51 mm) 0.19 0.64 1.08 1.13 1.06 1.06 1.00 Friction Loss & Recommended Maximum Duct Dimensions Without Reinforcement Friction Loss Ft./min. Hydraulic Diameter Velocity 10" 16" 24" 32" 40" 72" 100" 500 0.056 0.031 0.018 0.012 0.009 0.005 0.003 600 0.077 0.042 0.025 0.018 0.013 0.007 0.004 700 1.04 0.57 0.034 0.24 0.018 0.009 0.006 800 0.134 0.074 0.044 0.031 0.023 0.011 0.008 900 0.169 0.093 0.056 0.039 0.029 0.014 0.010 1000 0.207 0.114 0.068 0.048 0.036 0.018 0.012 2000 0.806 0.443 0.266 0.186 0.141 0.069 0.046 3000 1.797 0.988 0.594 0.415 0.315 0.153 0.103 4000 3.179 1.748 1.050 0.734 0.557 0.271 0.181 5000 4.952 2.724 1.636 1.143 0.867 0.422 0.283 Recommended Maximum Duct Dimensions Without Reinforcement* Internal Pressure Inches of Water EI-475-1" EI-800-1", 1 ½ ", 2" 13⁄16" 0.5 (125) † 1.0 (249) † 2.0 (498) † 0.5 (125) † 1.0 (249) † 2.0 (498) † 0.5 (125) † 1.0 (249) † Positive 36" (914 mm) 24" (610 mm) 15" (381 mm) 36" (914 mm) 24" (610 mm) 18" (457 mm) – 22" (558 mm) Negative 34" (864 mm) 24" (610 mm) 14" (356 mm) 36" (914 mm) 24" (610 mm) 18" (457 mm) 22" (558 mm) – *This table summarizes span/pressure limitations for unreinforced duct. For larger ducts, refer to NAIMA’s “Fibrous Glass Duct Construction Standard,” or Knauf Insulation's Air Duct Fabrication Manual. † (Pressure—Pascals [Pa]) All Product Resources January 2020 (PDF / 0.45MB) Data Sheet - Atmosphere Air Duct Board July 2011 (PDF / 0.15MB) UL Environmental Claim Validation - Formaldehyde Free - Atmosphere Air Duct Board November 2009 (PDF / 0.29MB) GREENGUARD Gold -Atmosphere Air Duct Board November 2009 (PDF / 0.28MB) GREENGUARD - Atmosphere Air Duct Board December 2019 (PDF / 1.67MB) Safety Data Sheet - Atmosphere Air Duct Board August 2012 (PDF / 0.16MB) UL Environmental Claim Validation - Recycled Content - Atmosphere Air Duct Board November 2015 (PDF / 0.16MB) UL Environmental Claim Validation - Mold Resistance - Atmosphere Air Duct Board September 2018 (PDF / 0.21MB) Submittal Sheet - Atmosphere Air Duct Board September 2017 (PDF / 0.15MB) Sell Sheet (Contractor) - Atmosphere Air Duct Board Need More Product Support? Reach out to our technical support team for product specs, installation guidance and more. Contact Tech Support Helpful Videos Glass Master Thickness Setup for Air Duct Boards Glass Master Spacing Setup for Air Duct Boards What is Glass Mineral Wool or Fiberglass Insulation Related Products Eclipse® Air Duct Board Used to fabricated air duct systems, this board provides excellent acoustic characteristics to help minimize noise. Applications HVAC Thickness 1"; 1.5"; 2" R-Value 4.3; 6.5; 8.7 Stiffness EI-475; EI-800 View Product Atmosphere™ Duct Liner Designed to offer excellent sound absorption, temperature control ...

atmosphere.knaufinsulation.us Whois

"domain_name": "knaufinsulation.us", "domain__id": "D3228851-US", "registrar": null, "registrar_id": null, "registrar_url": null, "status": "clientTransferProhibited https://icann.org/epp#clientTransferProhibited", "registrant_id": "CD81AC20270E64724A7A5019E11548A0B-NSR", "registrant_name": "Knauf Insulation Knauf Insulation", "registrant_address1": null, "registrant_address2": null, "registrant_city": "SHELBYVILLE", "registrant_state_province": "IN", "registrant_postal_code": "46176-8626", "registrant_country": "US", "registrant_country_code": null, "registrant_phone_number": null, "registrant_email": "darren.mahurin@knaufinsulation.com", "registrant_application_purpose": "P1", "registrant_nexus_category": "C21", "admin_id": null, "admin_name": null, "admin_address1": null, "admin_address2": null, "admin_city": null, "admin_state_province": null, "admin_postal_code": null, "admin_country": null, "admin_country_code": null, "admin_phone_number": null, "admin_email": null, "admin_application_purpose": null, "admin_nexus_category": null, "billing_id": null, "billing_name": null, "billing_address1": null, "billing_address2": null, "billing_city": null, "billing_state_province": null, "billing_postal_code": null, "billing_country": null, "billing_country_code": null, "billing_phone_number": null, "billing_email": null, "billing_application_purpose": null, "billing_nexus_category": null, "tech_id": null, "tech_name": null, "tech_address1": null, "tech_address2": null, "tech_city": null, "tech_state_province": null, "tech_postal_code": null, "tech_country": null, "tech_country_code": null, "tech_phone_number": null, "tech_email": null, "tech_application_purpose": null, "tech_nexus_category": null, "name_servers": [ "ns58.worldnic.com", "ns57.worldnic.com" ], "created_by_registrar": null, "last_updated_by_registrar": null, "creation_date": "2002-12-18 14:30:07", "expiration_date": "2020-12-17 23:59:59", "updated_date": "2019-01-28 17:14:45"